黄a大片av永久免费-亚洲熟妇色自偷自拍另类-中文字幕亚洲一区二区三区-国产精品麻花传媒二三区别

Welcome to Shenzhen Yuanxinda Electronic Instrument Co., Ltd.
深圳市源信達電子儀器有限公司
深圳市源信達電子儀器有限公司
Service Hotline
TEL:0755-85292815
Mobile:13590213125

products

Contact us

You are here:Home >> products >> Spectrum Analyzer...

Spectrum Analyzer

8560EC Portable Spectrum Analyzer

Model:
8560EC Portable Spectrum Analyzer
Product Brand:
Agilent
Fixed Telephone:
0755-85292815
Contact Number:
13590213125 (WeChat)
Contact QQ:
2538252977
Business Scope:
Leasing, sales, recycling, maintenance

    Agilent8560EC spectrum analyzer |Agilent 8560EC

    Frequency range (internal mixing):

    Agilent HP8560EC: 30 Hz connection scans to 2.9, 6.5, 13.2, 26.5, 40 or 50 GHz

    Agilent HP8561EC: 30Hz~6.5GHz

    Agilent HP8562EC: 30Hz~13.2GHz

    Agilent HP8563EC: 9kHz~26.5GHz; 30Hz~26.5GHz (option 006)

    Agilent HP8564EC: 9kHz~40GHz; 30Hz~40GHz (option 006)

    Agilent HP8565EC: 9kHz~50GHz; 30Hz~50GHz (option 006)


    頻率范圍(外混頻):

    18GHz~325GHz is divided into 12 waveguide frequency bands (cannot be provided by 8560EC option 002)

    General Specifications of Agilent HP8563EC Spectrum Analyzer

    Environmental Specifications of Agilent HP8563EC Spectrum Analyzer

    Calibration cycle: 2 years (8560EC/61EC/62EC/63EC); 1 year (8564EC/65EC)

    Warm-up time: 5 minutes under normal environmental conditions

    Temperature: -10°~+55℃ (when working); -51°~+71℃ (when not working)

    Humidity: 95%, 5 days at 40℃

    Water resistance: impervious to 16 liters/hour/ft2 of rain

    Height: 15,000 feet (when working); 50,000 feet (when not working)

    Impulse shock (half sine): 30g, lasting 11ms

    Transport trailer: 8-inch trailer with 6 sides and 8 corners

    Electromagnetic compatibility: Conducted and radiated interference comply with CISPR Pub.11 (1990). Except for some indicators, it meets the MIL-STD-461 C part4 standard.

    Power requirements

    Working with 115Vac: 90~140V rms, 3.2A rms max, 47~440Hz

    Work with 230Vac: 180~250V rms, 1.8Arms max, 47~66Hz

    Power consumption; 180W (8560EC/61EC/62EC/63EC); 260W (8564EC/65EC)

    Acoustic noise (rated value): at room temperature, intensity <5.0 Bel (ISODP 7779)

    Dimensions (without handle, bracket, mask): 337mm (width) × 187mm (height) × 461mm (length)

    Weight (handling weight, rated value): 20kg

    Option 002 built-in tracking generator (only for 8560EC)

    Frequency range: 300KHz~2.9GHz

    Accuracy (after taking the peak value): ±(reference frequency accuracy×tuning frequency+5%×interval+295Hz)

    Tracking drift (rated value): After 5 minutes of warm-up, it can be used for 1KHz RBW: After 30 minutes of heat prevention, it can be used for 300Hz RBW

    Small RBW: 300Hz amplitude

    Output level: -10~+1dBm; -10~2.8dBm (typical value) Resolution: 0.1dB accuracy (25℃±10℃)

    Fine adjustment: ±0.2dB/dB, ±0.5dBmax

    Accuracy: 0.75dB

    Level flatness: ±2.0dB

    Dynamic range: 95dB(300KHz~1MHz); 115dB(1MHz~2.0GHz); 110dB(2.0GHz~2.9GHz)

    Power scan: 10dB range, 0.1dB resolution input/output

    RF output (front panel): N type (female), 50Ω (rated)

    External ALC input (rear panel): BNC (female), used with negative detector

    Please submit your basic information, we will contact you as soon as possible!

    *

    *

    *

    *

Related products